Two-zone loading
For highly efficient two-zone loading of a buffer cylinder by a heat generator with return temperature increase as a mixed circuit and separate flue gas condenser or two return connections
Specialist partner access required
Specialist partner access required
Specialist partner access required
BAFA Funding Opportunity for Heating System Optimization Through Hydraulic Balancing and Installation of Separate Control Technology
rendeMIX Multi-Port Mixing Manifold with 3/3-Way Tangential Mixing Valve DN25×G1½(a) Ms Cast Iron (red adapter), valve stem and cover Ms58
For highly efficient two-zone charging of a buffer storage tank by a heat generator with return temperature boost as a mixing circuit and a separate flue gas condenser or two return connections
EMS 240 actuator, 230 V AC, 50 Hz, 3.5 VA, 3-point signal, 5 Nm (240 h), 240°, 93s<br/>Mixer assembly with 3 connections to the heat source and a separate charging circuit outlet, Cu Ø35×1, pipe spacing 100 mm, DN32×G1½(a) flat<br/>1 integrated backflow preventer, Dp 10 mbar, and 1 external flow-return differential pressure regulator, Dp 80 mbar at the mixing circuit flow (5), mounted in an Ms58 adapter, L 90 mm<br/>Generator circuit (HT-RLA): Kvs = 11.6 • V'max[250 mbar] = 5.8 m³/h • Q'max[20 K] = 135 kW • Leak rate < 0.1% - Condenser circuit (NT): Kvs = 9.2 × V'max[250 mbar] = 4.6 m³/h × Q'max[10K] = 53 kW<br/>6 thermometers 0–120°C, Ø63 mm, solder sleeves Ms58<br/>6 ball valve fittings, straight-through DN25s, PN20, G1½(i)×Rp1 flat-seal, stuffing box, stem with nylon T-handle<br/>EPP insulation shell 40 g/l, black, 300×450 mm, Quick-installation kit<br/>With G1½(i) pump flange for DN25 pump on the heat generator supply line (6)<br/>Assembly includes ONE PAS L180 pump compensator (Part No.: 001 338) and ONE pump compensator PAS L90 (Part No.: 001 347)—both with G1½(a)×G1½(i) screw connections for balancing a DN25 pump, length 180 mm/90 mm, insulated
Assembly does not include a pump
Model DN 25 – heavy-duty version, PN 10 bar, Tmax 120°C
CAUTION: DO NOT USE WITHOUT A SUPPLY TEMPERATURE LIMITER (VTB) THERMOSTATIC VALVE! Available in DN32s (Part No. 996 106), DN40s (Part No. 996 107), or DN50s (Part No. 996 108).
Generator circuit (HT-RLA): Kvs = 11.6 • V'max[250mbar] = 5.8m³/h • Q'max[20K] = 135kW • leakage rate < 0.1% - Condenser circuit (NT): Kvs = 9.2 • V'max[250mbar] = 4.6m³/h • Q'max[10K] = 53kW