VTR DN20 T60-90 Heating value set

Item no. 996 021 Valve technology
For constant control of the flow temperature with protection against condensation in calorific value boilers on buffer storage tanks (precise top loading) and prevention of cooling down of the buffer hot zone during pump run-down.

Recommended accessories

								

Thermostatic head setting limit

999920

Further information?

Further questions?

Contact technical support
					

Configure product variant

Nominal width

Product documentation

Tender text

Baunach article master data Version: 19.11.24

BAFA funding opportunity within the scope of heating system optimisation through hydraulic balancing and installation of technology for volume flow control

Thermostatic flow temperature controller with adjustable flow temperature

For constant control of the flow temperature with protection against condensation in calorific value boilers on buffer storage tanks (precise top loading) and prevention of cooling down of the buffer hot zone during pump run-down.

consisting of:

1) Three-way mixing valve, gunmetal, EPDM seal

G1 flat sealing, Z-dimensions: L 71.0mm × W 35.5mm

DN20, DpN 100mbar, Kvs = 3.5, V'max[100mbar] = 1.1m³/h, Q'max = 26kW [20K] = 11l/min [10/45°C]

PN 10bar, Tmax 120°C (part no. 996 017)

2) Thermostatic head with immersion sensor, setpoint range 60°C to 90°C

Capillary tube length 2m, immersion sensor length 125mm Ø11mm

Reaction time approx. 60s

PN 10bar, Tmax 100°C (part no. 996 014)

3) Immersion sleeve with screw-in nipple R½×186mm, brass (part no. 996 015)

4) Connection fittings:

a) 2x union nut compression fitting, flat sealing, DN20, G1xØ22 (part no. 996 041)

b) Screw nipple insert, flat sealing, R¾xDN20 (for union nut G1) (part no. 996 031)

5) T-piece black, TsF ¾x¾x½ (part no. 996 055)

6) Double nipple black, NDs R¾x¾ (spare T.No. 996 064)

Performance data

DN20, DpN 100mbar, Kvs = 3.5, V'max[100mbar] = 1.1m³/h, Q'max = 26kW [20K] = 11l/min [10/45°C]

Baunach