2valSYS DN25s 2x2 VR

Item no. 001 341 Manifold products
For controlling a mixed high-temperature circuit by means of high-efficiency operation of a system separation via flow control, the return of which is used highly efficiently by a rendeMIX heat distribution system

Accessories needed

								

ST DN25s AD200 P40 R 5

001069
								

ST DN25s AD200 P40 R

001067

Recommended accessories

								

Schl KuH DN32-50 set

996167
								

ISO KuH DN32 G1½(i)xRp1¼

996086

Further information?

Further questions?

Contact technical support
					

Configure product variant

Nominal width

DN25s

Performance class

Throttle circuit (HT) for ST on-site:
Kvs = 16.3 • V'max[100mbar] = 5.2m³/h
Q'max[20K] = 121kW • Q'max[10K] = 60kW

Flow direction producer

Flow direction Producer Right

Pump flange

Product documentation

Assembly instructions

Assembly instructions: For specialist partners only.
Please log in here or register here

Actuator three-way mixer: For specialist partners only.
Please log in here or register here

Spare parts drawing

Spare parts drawing For specialist partners only.
Please log in here or register here

Data sheet

001341_DBL_2022-01-30.pdf

GAEB

001341.D81

Tender text

Baunach article master data Version: 10.05.24

BAFA funding opportunity as part of heating system optimisation through hydraulic balancing and installation of separate control technology

rendeMIX 2-Wege-Drosselhahn DN32×G1½(a) Ms58, Küken und Deckel Ms58

For controlling a mixed high-temperature circuit by means of high-efficiency operation of a system separation via flow control, the return of which is used highly efficiently by a rendeMIX heat distribution system

Stellantrieb EMS 90-3P, 230V~ 50Hz 3,5VA 3-Punkt-Signal, 5Nm (240h), 90°, 70s, Adapter grau

Unmixed manifold assembly with 2 connections to the heat source, CuØ35×1, pipe distance to the heat source (manifold) 100mm, pipe distance to the 100mm, DN32×G1½(a) flat.

1 integrated gravity brake/backflow preventer, Dp10mbar

Throttle circuit (HT) for system separation on site: Kvs = 16.3 - V'max[100mbar] = 5.2m³/h - Q'max[20K] = 121kW - Q'max[10K] = 60kW - Leakage rate < 0,1%

2 Thermometers 0-120°C, Ø63mm, soldering sleeves Ms58

4 Kugelhahnverschraubungen, Durchgang DN32, PN25, G1½(i)×Rp1¼ flachdichtend, Stopfbuchse, Spindel mit 4-Kant Antrieb SW25

Insulating moulded tray EPP 40g/l, black, 300×450mm, quick assembly kit

Without pump flanges

Assembly does NOT include pump compensator - PAS L180 (Part No.: 001 338)

Assembly does not contain a pump

Model DN 25 - manifold assembly for manifold connection from RIGHT, PN 10bar, Tmax 120°C

ATTENTION: CANNOT BE USED WITHOUT SYSTEM SEPARATION!

Performance data

Throttle circuit (HT) for system separation on site: Kvs = 16.3 - V'max[100mbar] = 5.2m³/h - Q'max[20K] = 121kW - Q'max[10K] = 60kW - Leakage rate < 0,1%

Baunach