rMIX DN25 3x4+3mix L 35

Item number: 001 562

Two-zone discharge

For highly efficient two-zone discharging of a buffer cylinder in a mixed low-temperature circuit (2nd mixing circuit) with highly efficient use of the return flow of a mixed high-temperature circuit (1st mixing circuit)

Gross price €9,999.00
Your price
€9,999.00 plus VAT.
Delivery time depends on the recipient country

Product documentation

Assembly instructions

Assembly instructions for motors

Spare parts drawing

Tender text

BAFA Funding Opportunity for Heating System Optimization Through Hydraulic Balancing and Installation of Separate Control Technology<br/>rendeMIX Multi-Port Mixing Manifold with 3/3-Way Tangential Mixing Valve DN25×G1½(a) MsGuss (green adapter) and 3-way mixing valve DN32×G1½(a) Ms58, valve body and cover Ms58

For highly efficient two-zone discharge of a buffer tank in a mixed low-temperature circuit (2nd mixing circuit) with highly efficient utilization of the return flow from a mixed high-temperature circuit (1st mixing circuit)

1. Mixing circuit: Actuator EMS 90-3P, 230V~ 50Hz 3.5VA 3-point signal, 5Nm (240h), 90°, 70s, gray adapter. 2nd mixing circuit: EMS 240 actuator, 230 V~ 50 Hz, 3.5 VA, 3-point signal, 5 Nm (240 h), 240°, 93s<br/>Two-circuit manifold assembly with 3 connections to the heat generator (buffer tank or boiler with flue gas heat exchanger), Cu Ø35×1, pipe spacing 100 mm, DN32×G1½(a) flat<br/>2 integrated gravity brakes/backflow preventers, Dp 10 mbar<br/>1st mixing circuit (HT): Kvs = 12.5 &#x95; V'max[100 mbar] = 4 m³/h &#x95; Q'max[20K] = 93 kW &#x95; Leakage rate < 0.1% - 2nd mixing circuit (NT): Kvs = 6.2 &#x95; V'max[100 mbar] = 2 m³/h &#x95; Q'max[10 K] = 23 kW &#x95; Leak rate < 0.1%<br/>7 thermometers 0–120°C, Ø63 mm, solder sleeves Ms58<br/>7 ball valve fittings, straight-through DN25, PN32, G1½(i)×Rp1 flat-seal, stuffing box, sealing hole, stem with aluminum wing handle

EPP insulation shell 40 g/l, black, 450×450 mm, Quick-installation kit<br/>With G1½(i) pump flanges for DN25 pumps on the 1st mixed high- (3) and 2nd mixed low-temperature circuit supply lines (5)<br/>Assembly does NOT include a pump compensator—PAS L180 (Part No.: 001 338)<br/>Assembly does not include a pump<br/>Model DN 25 – lightweight version, PN 10 bar, Tmax 120°C

Performance data

1st mixing circuit (HT): Kvs = 12.5 • V'max[100mbar] = 4m³/h • Q'max[20K] = 93kW • leakage rate < 0.1% - 2nd mixing circuit (NT): Kvs = 6.2 • V'max[100mbar] = 2m³/h • Q'max[10K] = 23kW • leakage rate < 0.1%