Return utilization
For highly efficient use of the return flow of an unmixed high-temperature circuit (charging circuit) controlled by a changeover valve in a mixed low-temperature circuit (mixing circuit) by means of highly efficient operation of a system separation via flow control on a condensing boiler with minimum circulation
Specialist partner access required
Specialist partner access required
Specialist partner access required
Specialist partner access required
BAFA Funding Opportunity for Heating System Optimization Through Hydraulic Balancing and Installation of Separate Control Technology<br/>rendeMIX Multi-Port Mixing Manifold with 3/2-Way Tangential Mixing Valve DN25×G1½(a) MsGuss (green adapter) and 3-way mixing valve DN32×G1½(a) Ms58, valve body and cover Ms58<br/>For highly efficient utilization of the return flow from an unmixed high-temperature circuit (charging circuit) controlled by a diverter valve in a mixed low-temperature circuit (mixing circuit) by means of highly efficient operation of a system separation via flow control on a condensing boiler with minimum circulation<br/>Charging circuit: Actuator EMS 90-2P, 230V~ 50Hz 2.3VA 2-point signal, 6Nm (240h), 90°, 60s, right-closing, gray adapter. Mixing circuit: EMS 240 actuator, 230 V AC, 50 Hz, 3.5 VA, 3-point signal, 5 Nm (240 h), 240°, 93s<br/>Dual-circuit manifold assembly with 2 connections to the heat source and 4 connections to the heat sinks, Cu Ø35×1, DN32×G1½(a) flat, pipe spacing 100 mm<br/>1 integrated gravity brake/backflow preventer, Dp 10 mbar<br/>Heating circuit (HT): Kvs = 12.5 × V'max[100 mbar] = 4 m³/h × Q'max[20K] = 93 kW • Leak rate < 0.1% - Mixing circuit (low pressure) for system separation to be provided by the customer: Kvs = 9.4 • V'max[100 mbar] = 3 m³/h • Q'max[10 K] = 35 kW • Leak rate < 0.1%<br/>6 thermometers 0–120°C, Ø63 mm, solder sleeves Ms58<br/>6 ball valve fittings, straight-through DN25, PN32, G1½(i)×Rp1 flat-seal, stuffing box, sealing hole, stem with aluminum wing handle
Insulating molded shell, EPP 40 g/l, black, 450×450 mm, Quick-assembly kit<br/>Without pump flanges<br/>Assembly does NOT include a pump compensator – PAS L180 (Part No.: 001 338)<br/>Assembly does not include a pump<br/>Model DN 25 – lightweight version, PN 10 bar, Tmax 120°C<br/>CAUTION: CANNOT BE USED WITHOUT SYSTEM ISOLATION!
Charging circuit (HT): Kvs = 12.5 • V'max[100mbar] = 4m³/h • Q'max[20K] = 93kW • leakage rate < 0.1% - Mixing circuit (NT) for system separation on site: Kvs = 9.4 • V'max[100mbar] = 3m³/h • Q'max[10K] = 35kW • leakage rate < 0.1%