rJET DN25s 2x4 LH 1

Item number: 001 460

Return utilization

For highly efficient use of the return flow of an unmixed high temperature circuit in a mixed low temperature circuit by means of highly efficient operation of a system separation via flow control from the differential pressure of the pump in the heat generator circuit (i.e. without an additional pump in the primary circuit of the system separation!) at a condensing boiler, a stratified storage tank or a heat transfer station

Gross price €9,999.00
Your price
€9,999.00 plus VAT.
Delivery time depends on the recipient country

Product documentation

Assembly instructions

Assembly instructions for motors

Spare parts drawing

Tender text

BAFA Funding Opportunity for Heating System Optimization Through Hydraulic Balancing and Installation of Separate Control Technology

rendeMIX Multi-Port Mixing Manifold with 3/2-Way Tangential Mixing Valve DN25×G1½(a) Ms Cast Iron (red adapter), valve body and cover Ms58

For highly efficient utilization of the return flow from an unmixed high-temperature circuit in a mixed low-temperature circuit via highly efficient operation of a system separation using flow control based on the differential pressure of the pump in the heat generator circuit (i.e., without an additional pump in the primary circuit of the system separation!) on a condensing boiler, a stratified storage tank, or a heat transfer station

Actuator EMS 240, 230 V AC, 50 Hz, 3.5 VA, 3-point signal, 5 Nm (240 h), 240°, 93s<br/>Dual-circuit manifold assembly with 2 connections to the heat source and 4 connections to the heat sinks, Cu Ø35×1, DN32×G1½(a) flat, pipe spacing 100 mm<br/>1 integrated backflow preventer, Dp 10 mbar, and 1 integrated return differential pressure regulator, Dp 50–70 mbar<br/>Direct heating circuit (HT): Kvs = 9.2 × V'max[100 mbar] = 2.9 m³/h &#x95; Q'max[20 K] = 67 kW - Mixing circuit (NT) with ST DN25s: Kvs = 7.2 &#x95; V'max[100 mbar] = 2.3 m³/h &#x95; Q'max[10 K] = 27 kW &#x95; Leak rate < 0.1%<br/>6 thermometers 0–120°C, Ø63 mm, solder sleeves Ms58<br/>6 ball valve fittings, straight-through DN25s, PN20, G1½(i)×Rp1 flat-seal, stuffing box, stem with nylon T-handle<br/>EPP insulation mold, 40 g/l, black, 450×450 mm, Quick-installation kit<br/>With pump flange G1½(i) for DN25 pump on the heat generator supply line (1)

Assembly includes ONE pump compensator—PAS L180—with G1½(a)×G1½(i) threaded connections to compensate for a DN25 pump, length 180 mm, insulated (Part No.: 001 338)<br/>Assembly does not include a pump<br/>Model DN 25 – heavy-duty version, PN 10 bar, Tmax 120°C<br/>CAUTION: NOT TO BE USED WITHOUT SYSTEM ISOLATION!

Performance data

Direct heating circuit (HT): Kvs = 9.2 • V'max[100mbar] = 2.9m³/h • Q'max[20K] = 67kW - Mixing circuit (NT) with ST DN25s: Kvs = 7.2 • V'max[100mbar] = 2.3m³/h • Q'max[10K] = 27kW • Leakage rate < 0.1%