Two-zone loading
For highly efficient two-zone loading of a buffer cylinder by a heat generator with return temperature increase as a mixing circuit
Specialist partner access required
Specialist partner access required
Specialist partner access required
BAFA Funding Opportunity for Heating System Optimization Through Hydraulic Balancing and Installation of Separate Control Technology<br/>rendeMIX Multi-Port Mixing Manifold with 3/3-Way Tangential Mixing Valve DN25×G1½(a) Ms Cast Iron (green adapter), valve and cover Ms58<br/>For highly efficient two-zone charging of a buffer tank by a heat generator with return temperature increase as a mixing circuit<br/>Actuator EMS 240, 230 V AC, 50 Hz, 3.5 VA, 3-point signal, 5 Nm (240 h), 240°, 93s<br/>Return temperature boost mixing unit with 2 connections to the heat generator and 3 connections to the buffer tank, Cu Ø35×1, DN32×G1½(a) flat, pipe spacing 100 mm<br/>2 integrated gravity brakes/backflow preventers, Dp 10 mbar<br/>Generator circuit (HT-RLA): Kvs = 12.9 × V'max[250 mbar] = 6.5 m³/h • Q'max[20 K] = 151 kW • Q'max[10 K] = 76 kW • Leak rate < 0.1%<br/>5 thermometers 0–120°C, Ø63 mm, Ms58 solder sleeves<br/>5 ball valve fittings, straight-through DN25s, PN20, G1½(i)×Rp1 flat-seal, stuffing box, stem with nylon T-handle<br/>EPP insulation mold, 40 g/l, black, 300×450 mm, Quick-installation kit<br/>With G1½(i) pump flange for DN25 pump on the mixed heat generator return (5)<br/>Assembly does NOT include a pump compensator – PAS L180 (Part No.: 001 338)<br/>Assembly does not include a pump<br/>Model DN 25 – heavy-duty version, PN 10 bar, Tmax 120°C
Generator circuit (HT-RLA): Kvs = 12.9 • V'max[250mbar] = 6.5m³/h • Q'max[20K] = 151kW • Q'max[10K] = 76kW • Leakage rate < 0.1%