Product search
RTB DN15 T0-40 balancing valve (Fbh)
Configure product variant
Nominal width
Performance class
V'max[100mbar] = 0.57m³/h
Q'max = 9.3kW [20K] Q'max[10K] = 6.6kW
Product documentation
Tender text
Baunach article master data Version: 19.11.24
BAFA funding opportunity within the scope of heating system optimisation through hydraulic balancing and installation of technology for volume flow control
Thermostatic return temperature limiter for direct connection to the return collector of an underfloor heating system (Fbh) with Eurocone
For individual room control of floor and wall heating circuits and for hydraulic balancing of individual heat consumers.
Valve with adjustable maximum temperature, with approx. 0.1% fixed minimum flow rate
Adjustable return temperature: 0°C - 40°C
DN15, DpN 100mbar, V'maxN 0.57m³/h, Kvs 1.8, straight through, brass, EPDM seal
Inlet nipple G¾(a) for conical screw connection (Euro cone), e.g. KRV 18mm
Outlet fitting with union nut G¾(i) for Euro cone
PN 10bar, Tmax 90°C
Length: 72mm, height incl. thermostatic head: 67mm, width thermostatic head: 41mm
Performance data
DN15, DpN 100mbar, V'maxN 0.57m³/h, Kvs 1.8, straight through, brass, EPDM seal