rMIX DN50 3x2 VR

Item no. 001 801 Manifold products
For highly efficient use of the return flow of high-temperature circuits in a mixed low-temperature circuit (two- or three-chamber manifold) or for highly efficient two-zone discharge of a buffer tank through a mixed circuit (three-chamber manifold).
					

Configure product variant

Nominal width

DN50

Flow direction producer

Flow direction Producer Right

Pump flange

without (0)

Product documentation

GAEB

001801.D81

Tender text

Baunach article master data Version: 19.11.24

BAFA funding opportunity as part of heating system optimisation through hydraulic balancing and installation of separate control technology

rendeMIX multi-port mixing manifold consisting of two cascaded 3-way mixing valves DN50×FlPN6 grey cast iron, plug and cover grey cast iron

For highly efficient use of the return flow of high-temperature circuits in a mixed low-temperature circuit (two- or three-chamber manifold) or for highly efficient two-zone discharge of a buffer tank through a mixed circuit (three-chamber manifold).

Actuator EMS 90-3P, 230V~ 50Hz 3.5VA 3-point signal, 20Nm, 90°, 95s

Mixer assembly with 3 connections to the heat source, St-DN50, pipe spacing to heat source 290mm, pipe spacing to mixing circuit 580mm, DN50×FlPN6

without integrated gravity brake/backflow preventer

Mixing circuit (NT): Kvs = 28.3 • V'max[100mbar] = 8.9m³/h • Q'max[20K] = 208kW • Q'max[10K] = 104kW • Leakage rate < 0,1%

No thermometers

Without ball valve fitting

Without moulded insulating shell

With pump flange DN50 PN6

Assembly does NOT include pump compensator - PAS L180 (Part No.: 001 338)

Assembly does not contain a pump

Model DN 50 - Manifold assembly for manifold connection from RIGHT, PN 6bar, Tmax 120°C

Performance data

Mixing circuit (NT): Kvs = 28.3 • V'max[100mbar] = 8.9m³/h • Q'max[20K] = 208kW • Q'max[10K] = 104kW • Leakage rate < 0,1%