Flow Temperature Controller DN40 20–70°C
For draining a buffer tank. For a fresh water station with effective use of the middle buffer volume - The top of the buffer tank heats up faster, while the bottom stays cold longer -<br/>Thermostatic flow temperature control valve with adjustable mixing temperature 20–70°C. <br/>Consisting of:
1) Three-way mixing valve, red brass, EPDM seal
DN50, DpN 100 mbar, Kvs = 10, V'max[100 mbar] = 3.2 m³/h, Q'max = 74 kW [20 K] = 30 L/min [10/45°C]<br/>PN 10 bar, Tmax 120°C<br/>Mixes two inputs (marked red and blue) to the set temperature at the output (unmarked).<br/>2) Thermostat head with coil immersion sensor, setpoint range 20°C to 70°C<br/>Capillary tube length 2 m, coil immersion sensor length 125 mm, response time approx. 5 s, PN 10 bar, Tmax 90°C (Part No. 996 005)<br/>CAUTION: The immersion sensor comes into contact with the heating water—provide a shut-off valve on site!
3) Connection fittings:
3x screw nipple inserts, flat-sealing, R2
4) Sensor connection
Black T-fitting, TsF 2x2x½
DN50, DpN 100mbar, Kvs = 10, V'max[100mbar] = 3.2m³/h, Q'max = 74kW [20K] = 30l/min [10/45°C]