rMIX DN25s 2x4+3mix R 35

Item number: 001 783

Return utilization

For discharging a stratified storage tank in a mixed low temperature circuit (2nd mixing circuit) with highly efficient use of the return flow of a mixed high temperature circuit (1st mixing circuit) with the lowest possible return flow temperature

Gross price €9,999.00
Your price
€9,999.00 plus VAT.
Delivery time depends on the recipient country

Recommended accessories

Product documentation

Assembly instructions

Assembly instructions for motors

Spare parts drawing

Tender text

BAFA Funding Opportunity for Heating System Optimization Through Hydraulic Balancing and Installation of Separate Control Technology<br/>rendeMIX Multi-Port Mixing Manifold with 3/3-Way Tangential Mixing Valve DN25×G1½(a) MsGuss (red adapter) and 3-way mixing valve DN32×G1½(a) Ms58, valve body and cover Ms58

For discharging a stratified storage tank in a mixed low-temperature circuit (2nd mixing circuit) while making highly efficient use of the return flow from a mixed high-temperature circuit (1st mixing circuit) with the lowest possible return temperature

1st mixing circuit: EMS 90-3P actuator, 230V~ 50Hz 3.5VA 3-point signal, 5Nm (240h), 90°, 70s, gray adapter. 2nd mixing circuit: EMS 240 actuator, 230 V~ 50 Hz, 3.5 VA, 3-point signal, 5 Nm (240 h), 240°, 93s<br/>Dual-circuit manifold assembly with 2 connections to the heat source and 4 connections to the heat sinks, Cu Ø35×1, DN32×G1½(a) flat, pipe spacing 100 mm<br/>3 integrated gravity brakes/backflow preventers, Dp 10 mbar<br/>1. Mixing circuit (HT): Kvs = 13.3 &#x95; V'max[100 mbar] = 4.2 m³/h &#x95; Q'max[20K] = 98 kW × Leakage rate < 0.1% - 2. Mixing circuit (NT): Kvs = 12.9 × V'max[100 mbar] = 4.1 m³/h × Q'max[10 K] = 48 kW × Leak rate < 0.1%<br/>6 thermometers 0–120°C, Ø63 mm, solder sleeves Ms58<br/>6 ball valve fittings, straight-through DN25s, PN20, G1½(i)×Rp1 flat-seal, stuffing box, stem with nylon T-handle<br/>EPP insulation mold, 40 g/l, black, 450×450 mm, Quick-installation kit<br/>With G1½(i) pump flanges for DN25 pumps on the 1st mixed high-temperature (3) and 2nd mixed low-temperature circuit supply lines (5)

Assembly includes TWO pump compensators—PAS L180—with G1½(a)×G1½(i) screw connections for compensating a DN25 pump, length 180 mm, insulated (Part No.: 001 338)<br/>Assembly does not include a pump<br/>Model DN 25 – heavy-duty version, PN 10 bar, Tmax 120°C

Performance data

1st mixing circuit (HT): Kvs = 13.3 • V'max[100mbar] = 4.2m³/h • Q'max[20K] = 98kW • leakage rate < 0.1% - 2nd mixing circuit (NT): Kvs = 12.9 • V'max[100mbar] = 4.1m³/h • Q'max[10K] = 48kW • leakage rate < 0.1%