rSTOR C
For highly efficient two-zone discharge of an rSTOR C buffer storage tank in a mixed low-temperature circuit (2nd mixed circuit) through highly efficient operation of a system split via flow control, utilizing the return flow from a mixed high-temperature circuit highly efficiently, connected ABOVE a ball valve connection set (1st mixed circuit),
Specialist partner access required
Specialist partner access required
Specialist partner access required
BAFA Funding Opportunity for Heating System Optimization Through Hydraulic Balancing and Installation of Separate Control Technology<br/>rendeMIX Multi-Port Mixing Manifold with 3/2-Way Tangential Mixing Valve DN25×G1½(a) Ms Cast Iron (red adapter), valve and cover Ms58<br/>For highly efficient two-zone discharge of an rSTOR C buffer storage tank in a mixed low-temperature circuit (2nd mixing circuit) via highly efficient operation of a system separation using flow control, with highly efficient utilization of the return flow from a mixed high-temperature circuit; connection ABOVE a ball valve connection set (1st mixing circuit),
1. Mixing circuit: Actuator EMS 90-3P, 230V~ 50Hz 3.5VA 3-point signal, 5Nm (240h), 90°, 70s, gray adapter. 2nd mixing circuit: EMS 240 actuator, 230 V~ 50 Hz 3.5 VA 3-point signal, 5 Nm (240 h), 240°, 93s<br/>Dual-circuit manifold assembly with 3 connections to the heat generator (buffer tank or boiler with flue gas heat exchanger), Cu Ø35×1, pipe spacing 100 mm, DN32×G1½(a) flat<br/>2 integrated gravity brakes/backflow preventers, Dp 10 mbar<br/>1st mixing circuit (HT): Kvs = 12.5 • V'max[100 mbar] = 4 m³/h • Q'max[20K] = 93 kW • Leakage rate < 0.1% - 2nd mixing circuit (NT) for system separation to be provided by the customer: Kvs = 9.4 • V'max[100 mbar] = 3 m³/h • Q'max[10 K] = 35 kW • Leak rate < 0.1%<br/>7 thermometers 0–120°C, Ø63 mm, solder sleeves Ms58<br/>4 ball valve fittings, straight-through DN25, PN32, G1½(i)×Rp1 flat-seal, stuffing box, sealing hole, stem with aluminum wing handle
EPP insulation mold shell, 40 g/l, black, 450×450 mm, Quick-assembly kit<br/>Without pump flanges<br/>Assembly does NOT include pump compensator – PAS L180 (Part No.: 001 338)<br/>With blind fitting consisting of a G1½ brass union nut and a stainless steel washer<br/>Model DN 25—lightweight version, PN 10 bar, Tmax 120°C<br/>CAUTION: CANNOT BE USED WITHOUT SYSTEM ISOLATION!
1st mixing circuit (HT): Kvs = 12.5 • V'max[100mbar] = 4m³/h • Q'max[20K] = 93kW • leakage rate < 0.1% - 2nd mixing circuit (NT) for system separation on site: Kvs = 9.4 • V'max[100mbar] = 3m³/h • Q'max[10K] = 35kW • leakage rate < 0.1%